Parameters
List of parameters
1-160
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the saturated magnetizing inductance of the separately-excited synchronous motor quadrature to the rotor
direction (q axis).
This parameter value is automatically calculated using the motor model (p0340 = 1, 2).
Description: The saturation characteristics (flux as a function of the magnetizing current) is defined using 4 points.
This parameter specifies the y coordinate (flux) for the 1st value pair of the characteristic.
Sets the first flux value of the saturation characteristic as a [%] referred to the rated motor flux (100 %).
Dependency: The following applies for the flux values:
p0362 < p0363 < p0364 < p0365
Refer to: p0366
Note: For induction motors, p0362 = 100 % corresponds to the rated motor flux.
For separately-excited synchronous motors p0362 = 100% corresponds to an induced terminal voltage with the
magnitude of the rated motor voltage (under no-load conditions at the synchronous speed).
Description: The saturation characteristics (flux as a function of the magnetizing current) is defined using 4 points.
This parameter specifies the y coordinate (flux) for the 2nd value pair of the characteristic.
Sets the second flux value of the saturation characteristic as a [%] referred to the rated motor flux (100 %).
Dependency: The following applies for the flux values:
p0362 < p0363 < p0364 < p0365
Refer to: p0367
Note: For induction motors, p0363 = 100 % corresponds to the rated motor flux.
For separately-excited synchronous motors p0363 = 100% corresponds to an induced terminal voltage with the
magnitude of the rated motor voltage (under no-load conditions at the synchronous speed).
p0361[0...n] Motor magnetizing inductance q axis, saturated / Mot L_magn q sat
VECTOR Can be changed: C2(3), U, T Calculated: CALC_MOD_EQU Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 15_1 Unit selection: p0349
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
0.00000 [mH] 10000.00000 [mH] 0.00000 [mH]
p0362[0...n] Saturation characteristic flux 1 / Mot saturat.flux 1
VECTOR Can be changed: C2(3), U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: PEM Expert list: 1
Min Max Factory setting
10.0 [%] 300.0 [%] 60.0 [%]
p0363[0...n] Saturation characteristic flux 2 / Mot saturat.flux 2
VECTOR Can be changed: C2(3), U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: PEM Expert list: 1
Min Max Factory setting
10.0 [%] 300.0 [%] 85.0 [%]