Siemens SINAMICS S Series - p3667 VSM line filter overtemperature alarm threshold; VSMfilt_T A_thresh; p3667[0...n] VSM line filter overtemperature alarm threshold; VSMfilt_T A_thresh; p3668 VSM line filter overtemperature shutdown threshold; VSM filt_T F_thres; p3668[0...n] VSM line filter overtemperature shutdown threshold; VSM filt_T F_thres

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-727
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the alarm threshold for the KTY temperature sensor of the Voltage Sensing Module (VSM) to monitor the line
filter temperature.
Prerequisite:
A KTY84 sensor is connected and p3665 is set to 2.
Dependency: Refer to: p3665
Refer to: F34207
Description: Sets the alarm threshold for the KTY temperature sensor of the Voltage Sensing Module (VSM) to monitor the line
filter temperature.
Prerequisite:
A KTY84 sensor is connected and p3665 is set to 2.
Dependency: Refer to: p3665
Refer to: F34207
Description: Sets the shutdown threshold for the KTY temperature sensor of the VSM to monitor the line filter temperature.
Dependency: Refer to: p3667
Refer to: A34211
Description: Sets the shutdown threshold for the KTY temperature sensor of the VSM to monitor the line filter temperature.
Dependency: Refer to: p3667
Refer to: A34211
p3667 VSM line filter overtemperature alarm threshold / VSMfilt_T A_thresh
A_INF, S_INF Can be changed: T Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: 9886
P-Group: - Units group: 21_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
0 [°C] 301 [°C] 150 [°C]
p3667[0...n] VSM line filter overtemperature alarm threshold / VSMfilt_T A_thresh
VECTOR Can be changed: T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: p0150 Func. diagram: 9886
P-Group: - Units group: 21_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [°C] 301.00 [°C] 150.00 [°C]
p3668 VSM line filter overtemperature shutdown threshold / VSM filt_T F_thres
A_INF, S_INF Can be changed: T Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: 9886
P-Group: - Units group: 21_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
0 [°C] 301 [°C] 180 [°C]
p3668[0...n] VSM line filter overtemperature shutdown threshold / VSM filt_T F_thres
VECTOR Can be changed: T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: p0150 Func. diagram: 9886
P-Group: - Units group: 21_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [°C] 301.00 [°C] 180.00 [°C]