Siemens SINAMICS S Series - r7229[0...n] CO: Par_circuit phase current actual value sum U, V, W; I_phase sum UVW; r7230[0...n] CO: Par_circuit DC link voltage actual value; Vdc_act; r7231[0...n] CO: Par_circuit phase voltage actual value phase U; V_phase U act val; r7232[0...n] CO: Par_circuit phase voltage actual value phase V; V_phase V act val

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-901
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the measured sum of the currents in phases U, V and W as peak value.
The summed value of all power units is displayed in r0069[6].
Description: Displays the measured actual value of the DC link voltage.
The average value of all power units is displayed in r0070.
Description: Displays the actual voltage, phase U.
The average value of all power units is displayed in r0089[0].
Description: Displays the actual voltage, phase V.
The average value of all power units is displayed in r0089[1].
Description: Displays the actual voltage, phase W.
The average value of all power units is displayed in r0089[2].
r7229[0...n] CO: Par_circuit phase current actual value sum U, V, W / I_phase sum UVW
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 6_5 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7230[0...n] CO: Par_circuit DC link voltage actual value / Vdc_act
A_INF (Parallel),
B_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 5_2 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r7231[0...n] CO: Par_circuit phase voltage actual value phase U / V_phase U act val
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 5_3 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r7232[0...n] CO: Par_circuit phase voltage actual value phase V / V_phase V act val
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 5_3 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r7233[0...n] CO: Par_circuit phase voltage actual value phase W / V_phase W act val
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 5_3 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]