List of parameters
Parameters
1-901
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the measured sum of the currents in phases U, V and W as peak value.
The summed value of all power units is displayed in r0069[6].
Description: Displays the measured actual value of the DC link voltage.
The average value of all power units is displayed in r0070.
Description: Displays the actual voltage, phase U.
The average value of all power units is displayed in r0089[0].
Description: Displays the actual voltage, phase V.
The average value of all power units is displayed in r0089[1].
Description: Displays the actual voltage, phase W.
The average value of all power units is displayed in r0089[2].
r7229[0...n] CO: Par_circuit phase current actual value sum U, V, W / I_phase sum UVW
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 6_5 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7230[0...n] CO: Par_circuit DC link voltage actual value / Vdc_act
A_INF (Parallel),
B_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 5_2 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r7231[0...n] CO: Par_circuit phase voltage actual value phase U / V_phase U act val
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 5_3 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r7232[0...n] CO: Par_circuit phase voltage actual value phase V / V_phase V act val
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 5_3 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r7233[0...n] CO: Par_circuit phase voltage actual value phase W / V_phase W act val
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 5_3 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]