List of parameters
Parameters
1-63
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
[2] = Encoder 2 Encoder Data Set EDS effective
[3] = Encoder 3 Encoder Data Set EDS effective
Dependency: Refer to: p0186, p0187, p0188, p0189, r0838
Note: Value 99 means the following: No encoder assigned (not configured).
Description: Displays the effective Command Data Set (CDS).
Dependency: Refer to: p0810, p0811, r0836
Note: The Command Data Set selected using a binector input (e.g. p0810) is displayed using r0836.
Description: Displays the effective Drive Data Set (DDS).
Dependency: Refer to: p0820, p0821, p0822, p0823, p0824, r0837
Note: The drive data set changeover is suppressed when selecting the motor identification, during the rotating measure-
ment, the encoder calibration and the friction characteristic record.
Description: Displays the status word of the closed-loop control.
r0050.0...3 CO/BO: Command Data Set CDS effective / CDS effective
A_INF, B_INF,
SERVO, S_INF,
TM41, VECTOR
Can be changed: - Calculated: - Access level: 2
Data type: Unsigned8 Dynamic index: - Func. diagram: 8560
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 CDS eff., bit 0 On Off -
01 CDS eff., bit 1 On Off -
02 CDS eff., bit 2 On Off -
03 CDS eff., bit 3 On Off -
r0051.0...4 CO/BO: Drive Data Set DDS effective / DDS effective
SERVO, TM41, VEC-
TOR
Can be changed: - Calculated: - Access level: 2
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DDS eff., bit 0 On Off -
01 DDS eff., bit 1 On Off -
02 DDS eff., bit 2 On Off -
03 DDS eff., bit 3 On Off -
04 DDS eff., bit 4 On Off -
r0056.1...15 CO/BO: Status word, closed-loop control / ZSW cl-loop ctrl
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: 2526
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
01 De-magnetizing completed Yes No -
04 Magnetizing completed Yes No 2701
08 Field weakening active Yes No -
14 Vdc_max controller active Yes No -
15 Vdc_min controller active Yes No -