Parameters
List of parameters
1-308
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
r1050: Motor. potentiometer, setpoint after the ramp-function generator
Dependency: Refer to: p1071, r1073, r1078
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Sets the signal source for scaling the main setpoint.
Description: Displays the effective main setpoint. The value shown is the main setpoint after scaling.
Description: Displays the effective main setpoint. The value shown is the main setpoint after scaling.
Description: Sets the signal source for the supplementary setpoint.
Dependency: Refer to: p1076, r1077, r1078
Description: Sets the signal source for scaling the supplementary setpoint.
p1071[0...n] CI: Main setpoint scaling / Main setp scal
SERVO (Extended
setp), VECTOR
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 3030
P-Group: Setpoints Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 1
r1073 CO: Main setpoint effective / Main setpoint eff
SERVO (Extended
setp), VECTOR
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 3030
P-Group: Setpoints Units group: 3_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [RPM] - [RPM] - [RPM]
r1073 CO: Main setpoint effective / Main setpoint eff
SERVO (Extended
setp, Lin)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 3030
P-Group: Setpoints Units group: 4_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [m/min] - [m/min] - [m/min]
p1075[0...n] CI: Suppl setpoint / Suppl setpoint
SERVO (Extended
setp), VECTOR
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 1550, 3030
P-Group: Setpoints Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p1076[0...n] CI: Supplementary setpoint scaling / Suppl setp scal
SERVO (Extended
setp), VECTOR
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 3030
P-Group: Setpoints Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 1