List of parameters
Parameters
1-243
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the signal source to select the Drive Data Set, bit 4 (DDS, bit 4).
Dependency: Refer to: r0051, r0837
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Sets the freely-assignable motor number for the motor changeover.
Dependency: Refer to: p0827
Caution: When changing over motor data sets with the same motor number (e.g. star/delta changeover) and for a motor with
brake, the motor brake remains open during the changeover.
Note: When the motor data sets are changed-over, the following applies:
The same motor number signifies the same thermal model.
Description: Sets the bit number for every motor data set.
Example:
p0827[0] = 0: For MDS0, r0830.0 is switched.
p0827[1] = 5: For MDS1, r0830.5 is switched.
Dependency: Refer to: p0826, r0830
Note: A motor is only changed over (a new motor selected) after the pulses have been canceled.
When the motor data sets are changed-over, the following applies:
Bit numbers that are not identical, signify that the motor must be changed over.
Description: Sets the signal source for the feedback signal when changing over the motor.
For p0833.0 = 1 the following applies:
p0824[0...n] BI: Drive data set selection DDS bit 4 / DDS select., bit 4
SERVO, TM41, VEC-
TOR
Can be changed: C2(15), T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: CDS, p0170 Func. diagram: 8565
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p0826[0...n] Motor changeover, motor number / Mot_chng mot No.
SERVO, VECTOR Can be changed: C2(3), U Calculated: - Access level: 2
Data type: Unsigned16 Dynamic index: MDS, p0130 Func. diagram: 8575
P-Group: Motor Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 15 0
p0827[0...n] Motor changeover status word bit number / Mot_chg ZSW bitNo.
SERVO, VECTOR Can be changed: C2(3), U Calculated: - Access level: 2
Data type: Unsigned16 Dynamic index: MDS, p0130 Func. diagram: 8575
P-Group: Motor Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 15 0
p0828[0...n] BI: Motor changeover, feedback signal / Mot_chng fdbk sig
SERVO, VECTOR Can be changed: C2(3), T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: CDS, p0170 Func. diagram: 8575
P-Group: Motor Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS S Series and is the answer not in the manual?

Siemens SINAMICS S Series Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS S Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals