Siemens SINAMICS S Series - r0331[0...n] Motor magnetizing current;short-circuit current actual; Mot I_mag_ratedAct; r0332[0...n] Rated motor power factor; Mot cos_phi_rated; r0333[0...n] Rated motor torque; Mot M_rated

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-147
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Induction motor:
Displays the rated magnetizing current from p0320.
For p0320 = 0, the internally calculated magnetizing current is displayed.
Synchronous motor:
Displays the rated shirt-circuit current from p0320.
Dependency: If p0320 was not entered, then the parameter is calculated from the rating plate parameters.
Description: Displays the rated power factor for induction motors.
For IEC motors, the following applies (p0100 = 0):
For p0308 = 0, the internally-calculated power factor is displayed.
For p0308 > 0, this value is displayed.
For NEMA motors, the following applies (p0100 = 1):
For p0309 = 0, the internally-calculated power factor is displayed.
For p0309 > 0, this value is converted into the power factor and displayed.
Dependency: If p0308 is not entered, the parameter is calculated from the rating plate parameters.
Note: The parameter is not used for synchronous motors (p0300 = 2xx).
Description: Displays the rated motor torque.
Note: For induction and reluctance motors, r0333 is calculated from p0307 and p0311.
For synchronous motors, r0333 is calculated from p0305, p0316, p0327 and p0328. The result can deviate from the
input in p0312. If p0316 = 0, then r0333 = p0312 is displayed.
r0331[0...n] Motor magnetizing current/short-circuit current actual / Mot I_mag_ratedAct
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: 5722, 6722,
6724
P-Group: Motor Units group: - Unit selection: -
Not for motor type: REL, FEM Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r0332[0...n] Rated motor power factor / Mot cos_phi_rated
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: PEM, REL Expert list: 1
Min Max Factory setting
- - -
r0333[0...n] Rated motor torque / Mot M_rated
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 7_4 Unit selection: p0100
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Nm] - [Nm] - [Nm]