EasyManua.ls Logo

Siemens SINAMICS S Series - p0441[0...n] Encoder commissioning serial number part 1; Enc comm ser_no 1; p0442[0...n] Encoder commissioning serial number part 2; Enc comm ser_no 2; p0443[0...n] Encoder commissioning serial number part 3; Enc comm ser_no 3; p0444[0...n] Encoder commissioning serial number part 4; Enc comm ser_no 4

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-182
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Serial number part 1 of the encoder for the commissioning.
Dependency: Refer to: p0440, p0442, p0443, p0444, p0445, r0460, r0461, r0462, r0463, r0464
Refer to: F07414
Note: A value of zero is displayed if an encoder is not present.
Description: Serial number part 2 of the encoder for the commissioning.
Dependency: Refer to: p0440, p0441, p0443, p0444, p0445, r0460, r0461, r0462, r0463, r0464
Refer to: F07414
Note: A value of zero is displayed if an encoder is not present.
Description: Serial number part 3 of the encoder for the commissioning.
Dependency: Refer to: p0440, p0441, p0442, p0444, p0445, r0460, r0461, r0462, r0463, r0464
Refer to: F07414
Note: A value of zero is displayed if an encoder is not present.
Description: Serial number part 4 of the encoder for the commissioning.
Dependency: Refer to: p0440, p0441, p0442, p0443, p0445, r0460, r0461, r0462, r0463, r0464
Refer to: F07414
Note: A value of zero is displayed if an encoder is not present.
p0441[0...n] Encoder commissioning serial number part 1 / Enc comm ser_no 1
SERVO, VECTOR Can be changed: C2(4) Calculated: CALC_MOD_ALL Access level: 4
Data type: Unsigned32 Dynamic index: EDS, p0140 Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0000 hex FFFF FFFF hex 0000 hex
p0442[0...n] Encoder commissioning serial number part 2 / Enc comm ser_no 2
SERVO, VECTOR Can be changed: C2(4) Calculated: CALC_MOD_ALL Access level: 4
Data type: Unsigned32 Dynamic index: EDS, p0140 Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0000 hex FFFF FFFF hex 0000 hex
p0443[0...n] Encoder commissioning serial number part 3 / Enc comm ser_no 3
SERVO, VECTOR Can be changed: C2(4) Calculated: CALC_MOD_ALL Access level: 4
Data type: Unsigned32 Dynamic index: EDS, p0140 Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0000 hex FFFF FFFF hex 0000 hex
p0444[0...n] Encoder commissioning serial number part 4 / Enc comm ser_no 4
SERVO, VECTOR Can be changed: C2(4) Calculated: CALC_MOD_ALL Access level: 4
Data type: Unsigned32 Dynamic index: EDS, p0140 Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0000 hex FFFF FFFF hex 0000 hex

Table of Contents