Parameters
List of parameters
1-440
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the signal source for the scaling of the lower torque limiting to limit the speed controller output.
Description: Sets the signal source for the torque/force reduction when traversing to a fixed stop. This value is converted into a
factor and is interconnected to the scaling of the torque/force limits.
Dependency: Refer to: p1528, p1529, r1543, p1544, p1545
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Sets the signal source for the torque/force reduction when traversing to a fixed stop. This value is converted into a
factor and is interconnected to the scaling of the torque/force limits.
Dependency: Refer to: p1528, p1529, r1543, p1544, p1545
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Displays the internally converted factor to interconnect to the scaling of the torque/force limits.
Dependency: Refer to: p1528, p1529, p1542, p1544, p1545
p1541[0...n] CI: Torque limit. speed controller lower scaling / M_max nctr lowScal
VECTOR (n/M) Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 6060
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 1
p1542[0...n] CI: Travel to fixed stop torque reduction / TfS M_red
SERVO Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 5610
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p1542[0...n] CI: Travel to fixed stop force reduction / TfS F_red
SERVO (Lin) Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 5610
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
r1543 CO: Travel to fixed stop torque scaling / TfS M scal
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 5610
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]