Siemens SINAMICS S Series - p1541[0...n] CI: Torque limit. speed controller lower scaling; M_max nctr lowScal; p1542[0...n] CI: Travel to fixed stop torque reduction; TfS M_red; p1542[0...n] CI: Travel to fixed stop force reduction; TfS F_red; r1543 CO: Travel to fixed stop torque scaling; TfS M scal

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-440
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the signal source for the scaling of the lower torque limiting to limit the speed controller output.
Description: Sets the signal source for the torque/force reduction when traversing to a fixed stop. This value is converted into a
factor and is interconnected to the scaling of the torque/force limits.
Dependency: Refer to: p1528, p1529, r1543, p1544, p1545
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Sets the signal source for the torque/force reduction when traversing to a fixed stop. This value is converted into a
factor and is interconnected to the scaling of the torque/force limits.
Dependency: Refer to: p1528, p1529, r1543, p1544, p1545
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Displays the internally converted factor to interconnect to the scaling of the torque/force limits.
Dependency: Refer to: p1528, p1529, p1542, p1544, p1545
p1541[0...n] CI: Torque limit. speed controller lower scaling / M_max nctr lowScal
VECTOR (n/M) Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 6060
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 1
p1542[0...n] CI: Travel to fixed stop torque reduction / TfS M_red
SERVO Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 5610
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p1542[0...n] CI: Travel to fixed stop force reduction / TfS F_red
SERVO (Lin) Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 5610
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
r1543 CO: Travel to fixed stop torque scaling / TfS M scal
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 5610
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]