Loading...
Function Diagrams
Vector control
2-1296
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-177 6490 – Speed control configuration
- 6490 -
Function diagram
87654321
fp_6490_51_eng.vsd
DO: VECTOR, VECTORGL, VECTORMV
SINAMICS
19.07.06 V02.05.00
Vector control - Speed control configuration
1
2
3
1 = Automatic Kp/Tn adaptation active
Meaning
1 = Sensorless vector control, freeze I component
1 = Acceleration pre-control, external source (p1495)
0 = Acceleration pre-control, internal source (n_set)
1 = Reference model, speed setpoint I component ON
Reserved
0
Bit No.
4
Speed control configuration
0
0
0
1
[6040.3]
[6040.3]
n_ctrl config
p1400[D]
Factory setting
[6030.5]
6
7
1 = Kp/Tn adaptation active
1 = Free Tn adaptation active
Reserved
Reserved8
1
0
5
10
11
Reserved
Reserved
Reserved
Reserved12
9
13
14
Reserved
1 = Torque pre-control always active
0 = Torque pre-control for n_ctrl enabled
0
15 1 = Sensorless vector control, speed pre-control active 1
Refer to [1020.7]
p0115[y] (Motor Modules)
[6031.1][6031.7]
[6031.2]
[6050.6]
[6060.4]
[6040.3]

Table of Contents