List of parameters
Parameters
1-167
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the rated current (I_F) for the excitation.
Description: Sets the starting point of the current-dependent current controller adaptation where the current controller gain
p1715 is effective.
Dependency: Refer to: p0392, p0393, p1402, p1715
Caution: This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
Note: For p0393 = 100 % or p1402 bit 2 = 0, the current controller adaptation is disabled and p1715 is effective over the
entire range.
Description: Sets the starting point of the current-dependent current controller adaptation where the current controller gain
p1715 is effective.
Dependency: Refer to: p0392, p0393, p1402, p1715
Caution: This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
Description: Sets the starting point of the current-dependent current controller adaptation where the adapted current controller
gain p1715 * p0393 is effective.
Dependency: Refer to: p0391, p0393, p1402, p1715
Caution: This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
p0390[0...n] Rated excitation current / Exc I_rated
VECTOR Can be changed: C2(1, 3) Calculated: - Access level: 1
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: 6727
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
0.00 [A] 10000.00 [A] 0.00 [A]
p0391[0...n] Current controller adaptation, starting point KP / I_adapt pt KP
SERVO Can be changed: C2(3), U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: 5714
P-Group: Motor Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.00 [Arms] 6000.00 [Arms] 0.00 [Arms]
p0391[0...n] Current controller adaptation, starting point KP / I_adapt pt KP
VECTOR Can be changed: C2(3), U, T Calculated: CALC_MOD_REG Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: 6714
P-Group: Motor Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.00 [Arms] 6000.00 [Arms] 0.00 [Arms]
p0392[0...n] Current controller adaptation, starting point KP adapted / I_adapt pt KP adap
SERVO Can be changed: C2(3), U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: 5714
P-Group: Motor Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.00 [Arms] 6000.00 [Arms] 0.00 [Arms]