Parameters
List of parameters
1-532
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: The serial interface for the debug monitor is COM1 (X140) or COM2 (internal).
Value = 0: COM2 (internal)
Value = 1: COM1 (X140), PPI is de-activated
Description: Sets the monitoring time to monitor the process data received via COMM BOARD. If no process data is received
within this time, an appropriate message is output.
Dependency: Refer to: F08501
Note: 0: The monitoring is deactivated.
Description: Sets the PROFIBUS Ident Number (PNO-ID).
SINAMICS can be operated with various identities on PROFIBUS. This allows the use of a PROFIBUS GSD that is
independent of the device (e.g. PROFIdrive VIK-NAMUR with Ident Number 3AA0 hex).
Values: 0: SINAMICS S/G
1: VIK-NAMUR
Note: A new setting only becomes effective after POWER ON, reset or download.
p2039 Select debug monitor interface / Sel. debug monitor
CU_S Can be changed: U, T Calculated: - Access level: 4
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 0
p2040 COMM INT monitoring time / C INT t_monit
CU_CX32, CU_LINK Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 [ms] 65535000 [ms] 20 [ms]
p2041[0...4] PROFIBUS detail settings / PB detail
CU_S Can be changed: U, T Calculated: - Access level: 4
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 65535 0
p2042 PROFIBUS Ident Number / PB Ident No.
CU_S Can be changed: C1(1) Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 0