Parameters
List of parameters
1-112
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
6: MICROMASTER 440 PX
7: MICROMASTER 430
100: SINAMICS S
101: SINAMICS S
120: PM340 (SINAMICS S120)
150: SINAMICS G
200: SINAMICS GM
250: SINAMICS SM
300: SINAMICS GL
Note: For parallel circuit configurations, the parameter index is assigned to a power unit.
Description: Displays the properties supported by the power unit hardware.
Note: For parallel circuit configurations, the parameter index is assigned to a power unit.
Description: Overloading the load duty cycles applies under the prerequisite that before and after the overload, the drive con-
verter is operated with its base load current - in this case, a load duty cycle of 300 s is used as basis.
For booksize drive units, the following applies:
Only the setting p0205 = 0 can be selected. In this particular case, the base load current has a load duty cycle of
150 % for 60 s and 176 % for 30 s.
For chassis drive units, the following applies:
The base load current for a slight overload condition is based on a load duty cycle 110 % for 60 s and 150 % for 10
s.
The base load current for a high overload condition is based on a load duty cycle 150 % for 60 s and 160 % for 10 s.
Values: 0: Load duty cycle with high overload for vector drives
1: Load duty cycle with low overload for vector drives
6: S1 duty cycle for servo drives (feed drive)
7: S6 duty cycle for servo drives (spindle drive)
r0204[0...n] Power unit hardware properties / PU HW property
A_INF, B_INF,
SERVO, S_INF,
VECTOR
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: PDS, p0120 Func. diagram: -
P-Group: Converter Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Device type DC/AC device AC/AC device -
01 RFI filter available Yes No -
02 Active Line Module available Yes No -
03 Smart Line Module available Yes No -
04 Basic Line Module available with thyristor
bridge
Yes No -
05 Basic Line Module available with diode
bridge
Yes No -
06 Liquid cooling Yes No -
08 Internal Braking Module Yes No -
09 Different cooling type supported Yes No -
12 Safe Brake Control (SBC) supported No Yes -
p0205 Power unit application / PU application
VECTOR Can be changed: C2(1) Calculated: - Access level: 2
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Converter Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 7 6