List of parameters
Parameters
1-763
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note: BI: p3873 = 1 signal --> closed-loop control with encoder
BI: p3873 = 0 signal --> sensorless closed-loop control
For a 0/1 edge, the commutation angle is set from CI: p3874.
Description: Sets the signal source for the commutation angle for operation with encoder.
Dependency: Refer to: p3870, p3871, p3872, p3873, r3875, p3876, p3878, p3879
Note: This angle is set for a 0/1 signal edge via BI: p3873.
Description: Displays the status word for long stator motors.
Dependency: Refer to: p3870, p3871, p3872, p3873, p3874, p3876, p3878, p3879
Note: The display is updated with a sampling time of 1 ms.
Re bit 00 = 1:
The encoder is parked. Contrary to r0481.14, parking is also displayed here if the suppression of the parking bit is
active in r0481.14 (p3870.1 = 1).
Re bit 01 = 1:
The long-stator functions requested closed-loop speed control with encoder. In r1407.2, it is indicated as to whether
an encoder is actually used for the closed-loop control.
Description: Displays the status word for long stator motors.
Dependency: Refer to: p3870, p3871, p3872, p3873, p3874, p3876, p3878, p3879
Note: The display is updated with a sampling time of 1 ms.
p3874 CI: Long stator signal source commutation angle oper. with encoder /
S_src com_ang enc
SERVO Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 3879[0]
r3875.0...1 CO/BO: Long stator status word / Long stator ZSW
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Sensor Module is unparked Yes No -
01 Closed-loop speed control with encoder
requested
Active Inactive -
r3875.0...1 CO/BO: Long stator status word / Long stator ZSW
SERVO (Lin) Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Sensor Module is unparked Yes No -
01 Closed-loop velocity control with encoder
requested
Active Inactive -