Siemens SINAMICS S Series - p3874 CI: Long stator signal source commutation angle oper. with encoder; S_src com_ang enc; r3875.0...1 CO;BO: Long stator status word; Long stator ZSW

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-763
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note: BI: p3873 = 1 signal --> closed-loop control with encoder
BI: p3873 = 0 signal --> sensorless closed-loop control
For a 0/1 edge, the commutation angle is set from CI: p3874.
Description: Sets the signal source for the commutation angle for operation with encoder.
Dependency: Refer to: p3870, p3871, p3872, p3873, r3875, p3876, p3878, p3879
Note: This angle is set for a 0/1 signal edge via BI: p3873.
Description: Displays the status word for long stator motors.
Dependency: Refer to: p3870, p3871, p3872, p3873, p3874, p3876, p3878, p3879
Note: The display is updated with a sampling time of 1 ms.
Re bit 00 = 1:
The encoder is parked. Contrary to r0481.14, parking is also displayed here if the suppression of the parking bit is
active in r0481.14 (p3870.1 = 1).
Re bit 01 = 1:
The long-stator functions requested closed-loop speed control with encoder. In r1407.2, it is indicated as to whether
an encoder is actually used for the closed-loop control.
Description: Displays the status word for long stator motors.
Dependency: Refer to: p3870, p3871, p3872, p3873, p3874, p3876, p3878, p3879
Note: The display is updated with a sampling time of 1 ms.
p3874 CI: Long stator signal source commutation angle oper. with encoder /
S_src com_ang enc
SERVO Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 3879[0]
r3875.0...1 CO/BO: Long stator status word / Long stator ZSW
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Sensor Module is unparked Yes No -
01 Closed-loop speed control with encoder
requested
Active Inactive -
r3875.0...1 CO/BO: Long stator status word / Long stator ZSW
SERVO (Lin) Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Sensor Module is unparked Yes No -
01 Closed-loop velocity control with encoder
requested
Active Inactive -