List of parameters
Parameters
1-429
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the signal source for the upper torque limit.
Dependency: Refer to: p1520, p1521, p1523
Danger: Negative values. that are obtained as a result of the signal source and the scaling can cause the motor to acceler-
ate in an uncontrollable fashion.
Description: Sets the signal source for the lower or torque/force limit when regenerating.
Dependency: p1400 bit 4 = 0: Upper / lower
p1400 bit 4 = 1: Motoring / generating
Refer to: p1520, p1521, p1522, p1532
Danger: For p1400.4 = 0 (torque limiting, upper/lower) the following applies:
Positive values. that are obtained as a result of the signal source and the scaling can cause the motor to accelerate
in an uncontrollable fashion.
Description: Sets the signal source for the lower or torque/force limit when regenerating.
Dependency: p1400 bit 4 = 0: Upper / lower
p1400 bit 4 = 1: Motoring / generating
Refer to: p1520, p1521, p1522, p1532
Danger: For p1400.4 = 0 (torque/force limiting, upper/lower) the following applies:
Positive values. that are obtained as a result of the signal source and the scaling can cause the motor to accelerate
in an uncontrollable fashion.
p1522[0...n] CI: Torque limit upper / M_max upper
VECTOR (n/M) Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 6630
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 1520[0]
p1523[0...n] CI: Torque limit lower/regenerative / M_max lower/regen
SERVO Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 1610, 5620,
5630, 6630
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 1521[0]
p1523[0...n] CI: Force limit lower/regenerative / F_max lower/regen
SERVO (Lin) Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 1610, 5620,
5630, 6630
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 1521[0]