List of parameters
Parameters
1-791
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note: DO: Digital Output
DI/DO: Bidirectional Digital Input/Output
Description: Setting to invert the signals at the digital outputs of terminal module 41 (TM41).
Note: DO: Digital Output
DI/DO: Bidirectional Digital Input/Output
Description: Setting to invert the signals at the digital inputs/outputs of terminal module 17 (TM17).
Note: DI/DO: Bidirectional Digital Input/Output
Bit field: Bit Signal name 1 signal 0 signal FP
00 DO 0 (X542.1 - 3) Inverted Not inverted -
01 DO 1 (X542.4 - 6) Inverted Not inverted -
08 DI/DO 8 (X541.2) Inverted Not inverted -
09 DI/DO 9 (X541.3) Inverted Not inverted -
10 DI/DO 10 (X541.4) Inverted Not inverted -
11 DI/DO 11 (X541.5) Inverted Not inverted -
p4048 TM41 invert digital outputs / TM41 DO invert
TM41 Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
08 DI/DO 0 (X521.1) Inverted Not inverted 9661
09 DI/DO 1 (X521.2) Inverted Not inverted 9661
10 DI/DO 2 (X521.3) Inverted Not inverted 9662
11 DI/DO 3 (X521.4) Inverted Not inverted 9662
p4048 TM17 invert digital inputs/outputs / TM17 DI/DO invert
TM17 Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI/DO 0 (X520.2) Inverted Not inverted -
01 DI/DO 1 (X520.3) Inverted Not inverted -
02 DI/DO 2 (X520.5) Inverted Not inverted -
03 DI/DO 3 (X520.6) Inverted Not inverted -
04 DI/DO 4 (X520.8) Inverted Not inverted -
05 DI/DO 5 (X520.9) Inverted Not inverted -
06 DI/DO 6 (X521.2) Inverted Not inverted -
07 DI/DO 7 (X521.3) Inverted Not inverted -
08 DI/DO 8 (X521.8) Inverted Not inverted -
09 DI/DO 9 (X521.9) Inverted Not inverted -
10 DI/DO 10 (X522.2) Inverted Not inverted -
11 DI/DO 11 (X522.3) Inverted Not inverted -
12 DI/DO 12 (X522.5) Inverted Not inverted -
13 DI/DO 13 (X522.6) Inverted Not inverted -
14 DI/DO 14 (X522.8) Inverted Not inverted -
15 DI/DO 15 (X522.9) Inverted Not inverted -