Siemens SINAMICS S Series - p0645[0...n] Motor-torque characteristic kT1; Mot kT1; p0646[0...n] Motor-torque characteristic kT3; Mot kT3; p0647[0...n] Motor-torque characteristic kT5; Mot kT5

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-218
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the constant kT1 for the torque characteristic:
kT(iq)=kT1+kT3*iq^2+kT5*iq^4+kT7*iq^6
Dependency: Refer to: p0646, p0647, p0648
Description: Sets the constant kT1 for the torque characteristic:
kT(iq)=kT1+kT3*iq^2+kT5*iq^4+kT7*iq^6
Dependency: Refer to: p0646, p0647, p0648
Description: Sets the constant kT3 for the torque characteristic:
kT(iq)=kT1+kT3*iq^2+kT5*iq^4+kT7*iq^6
Dependency: Refer to: p0645, p0647, p0648
Description: Sets the constant kT5 for the torque characteristic:
kT(iq)=kT1+kT3*iq^2+kT5*iq^4+kT7*iq^6
Dependency: Refer to: p0645, p0646, p0648
p0645[0...n] Motor-torque characteristic kT1 / Mot kT1
SERVO (Exp M_ctrl) Can be changed: C2(1, 3), U, T Calculated: - Access level: 1
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, REL, FEM Expert list: 1
Min Max Factory setting
0.00 [Nm/A] 200.00 [Nm/A] 0.00 [Nm/A]
p0645[0...n] Motor-torque characteristic kT1 / Mot kT1
SERVO (Exp M_ctrl,
Lin)
Can be changed: C2(1, 3), U, T Calculated: - Access level: 1
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, REL, FEM Expert list: 1
Min Max Factory setting
0.00 [N/Arms] 200.00 [N/Arms] 0.00 [N/Arms]
p0646[0...n] Motor-torque characteristic kT3 / Mot kT3
SERVO (Exp M_ctrl) Can be changed: C2(1, 3), U, T Calculated: - Access level: 1
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, REL, FEM Expert list: 1
Min Max Factory setting
- - -
p0647[0...n] Motor-torque characteristic kT5 / Mot kT5
SERVO (Exp M_ctrl) Can be changed: C2(1, 3), U, T Calculated: - Access level: 1
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, REL, FEM Expert list: 1
Min Max Factory setting
- - -