Parameters
List of parameters
1-218
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the constant kT1 for the torque characteristic:
kT(iq)=kT1+kT3*iq^2+kT5*iq^4+kT7*iq^6
Dependency: Refer to: p0646, p0647, p0648
Description: Sets the constant kT1 for the torque characteristic:
kT(iq)=kT1+kT3*iq^2+kT5*iq^4+kT7*iq^6
Dependency: Refer to: p0646, p0647, p0648
Description: Sets the constant kT3 for the torque characteristic:
kT(iq)=kT1+kT3*iq^2+kT5*iq^4+kT7*iq^6
Dependency: Refer to: p0645, p0647, p0648
Description: Sets the constant kT5 for the torque characteristic:
kT(iq)=kT1+kT3*iq^2+kT5*iq^4+kT7*iq^6
Dependency: Refer to: p0645, p0646, p0648
p0645[0...n] Motor-torque characteristic kT1 / Mot kT1
SERVO (Exp M_ctrl) Can be changed: C2(1, 3), U, T Calculated: - Access level: 1
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, REL, FEM Expert list: 1
Min Max Factory setting
0.00 [Nm/A] 200.00 [Nm/A] 0.00 [Nm/A]
p0645[0...n] Motor-torque characteristic kT1 / Mot kT1
SERVO (Exp M_ctrl,
Lin)
Can be changed: C2(1, 3), U, T Calculated: - Access level: 1
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, REL, FEM Expert list: 1
Min Max Factory setting
0.00 [N/Arms] 200.00 [N/Arms] 0.00 [N/Arms]
p0646[0...n] Motor-torque characteristic kT3 / Mot kT3
SERVO (Exp M_ctrl) Can be changed: C2(1, 3), U, T Calculated: - Access level: 1
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, REL, FEM Expert list: 1
Min Max Factory setting
- - -
p0647[0...n] Motor-torque characteristic kT5 / Mot kT5
SERVO (Exp M_ctrl) Can be changed: C2(1, 3), U, T Calculated: - Access level: 1
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, REL, FEM Expert list: 1
Min Max Factory setting
- - -