Siemens SINAMICS S Series - p4069[0...1] BI: TM31 analog inputs, signal source for enable; TM31 AI enable; p4069[0...0] BI: TM41 analog input, signal source for enable; TM41 AI enable; p4071[0...1] CI: TB30 analog outputs, signal source; TB30 AO sig_source; p4071[0...1] CI: TM31 analog outputs, signal source; TM31 AO sig_source

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-805
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the signal source for the enable signal of the analog inputs of terminal module 31 (TM31).
Index: [0] = AI 0 (X521.1/X521.2, S5.0)
[1] = AI 1 (X521.3/X521.4, S5.1)
Description: Sets the signal source for the enable signal of the analog input of terminal module 41 (TM41).
Index: [0] = AI 0 (X523.1/X523.2)
Description: Sets the signal source for the analog outputs of the Terminal Board 30 (TB30).
Index: [0] = AO 0 (X482.5/X482.6)
[1] = AO 1 (X482.7/X482.8)
Note: AO: Analog Output
Description: Sets the signal source for the analog outputs of terminal module 31 (TM31).
Index: [0] = AO 0 (X522.1, X522.2, X522.3)
[1] = AO 1 (X522.4, X522.5, X522.6)
Note: AO: Analog Output
p4069[0...1] BI: TM31 analog inputs, signal source for enable / TM31 AI enable
TM31 Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 9566, 9568
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 1
p4069[0...0] BI: TM41 analog input, signal source for enable / TM41 AI enable
TM41 Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 9663
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 1
p4071[0...1] CI: TB30 analog outputs, signal source / TB30 AO sig_source
TB30 Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 / FloatingPoint32 Dynamic index: - Func. diagram: 1790, 9106
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p4071[0...1] CI: TM31 analog outputs, signal source / TM31 AO sig_source
TM31 Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 / FloatingPoint32 Dynamic index: - Func. diagram: 1840, 9572
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0