List of parameters
Parameters
1-49
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the smoothed actual value of the modulation depth.
Dependency: Refer to: r0074
Note: A_INF: Smoothing time constant = 300 ms
SERVO, VECTOR: Smoothing time constant = 100 ms
The signal is not suitable as process quantity and may only be used as display quantity.
The modulation depth is available smoothed (r0028) and unsmoothed (r0074).
Description: Displays the smoothed actual value of the reactive current component.
Note: Smoothing time constant = 300 ms
The signal is not suitable as process quantity and may only be used as display quantity.
The reactive current actual value is available smoothed (r0029) and unsmoothed (r0076).
Description: Displays the smoothed field-generating actual current.
Dependency: Refer to: r0076
Note: SERVO: Smoothing time constant = 100 ms
VECTOR: Smoothing time constant = 300 ms
The signal is not suitable as process quantity and may only be used as display quantity.
The field-generating current actual value is available smoothed (r0029) and unsmoothed (r0076).
Description: Displays the smoothed actual value of the active current components.
Dependency: Refer to: r0078
r0028 Modulation depth smoothed / Modulat depth smth
A_INF, SERVO,
VECTOR
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 5730, 6799,
8950
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r0029 Reactive current actual value smoothed / I_react smooth
A_INF, S_INF Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 8850, 8950
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r0029 Current actual value field-generating smoothed / Id_act smooth
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 5730, 6799
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r0030 Active current actual value smoothed / I_active smooth
A_INF, S_INF Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 8850, 8950
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]