Parameters
List of parameters
1-206
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the velocity actual value measured using the BERO.
Dependency: Refer to: p0580, p0583
Note: For p0580 = 0 (no measuring probe), a value of zero is displayed here.
Description: Displays the time between the last two BERO pulses.
The measuring time is specified as 32-bit value with a resolution of 1/48 µs.
If a new pulse is not received before the maximum measured time in p0583 expires, then r0587 is set to the maxi-
mum measuring time.
Dependency: Refer to: p0580
Note: For p0580 = 0 (no measuring probe), a value of zero is displayed here.
Description: Displays the number of measuring pulses that have occurred (been received) up until now.
Dependency: Refer to: p0580
Note: After reaching 4294967295 (2^32 - 1), the counter starts again at 0.
Description: Displays the time since the last measuring pulse was detected.
The delay time is specified as 32-bit value with a resolution of 1/48 µs.
When a measuring pulse occurs (is received) the delay time is reset and is limited to the maximum measuring time
in p0583.
Dependency: Refer to: p0580
Note: For p0580 = 0 (no measuring probe), a value of zero is displayed here.
r0586 CO: Measuring probe, velocity actual value / MT v_act
SERVO (Lin) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: 4_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [m/min] - [m/min] - [m/min]
r0587 CO: Measuring probe, measuring time measured / MT t_meas measured
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r0588 CO: Measuring probe, pulse counter / MT pulse counter
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r0589 Measuring probe, delay time / MT t_delay
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -