Description: Displays the changes of the safety message buffer. This counter is incremented every time that the safety message
buffer changes.
Recommend.: This is used to check whether the safety message buffer has been read-out consistently.
Dependency: Refer to: r9747, r9748, r9749, p9752, r9753, r9754, r9755, r9756, p9759
Description: Displays the numbers of safety messages that have occurred.
Dependency: Refer to: r9744, r9748, r9749, p9752, r9753, r9754, r9755, r9756, p9759
Note: The messages type "safety message" (Cxxxxx) are entered in the message fault buffer.
Description: Displays the relative system runtime in milliseconds when the safety message occurred.
Dependency: Refer to: r9744, r9747, r9749, p9752, r9753, r9754, r9755, r9756, p9759
Description: Displays the additional information about the safety message that occurred (as integer number).
Dependency: Refer to: r9744, r9747, r9748, p9752, r9753, r9754, r9755, r9756, p9759
r9744 SI message buffer changes, counter / SI msg_buffer chng
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Messages Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r9747[0...63] SI message code / SI msg_code
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Messages Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r9748[0...63] SI message time received in milliseconds / SI t_msg recv ms
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Messages Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [ms] - [ms] - [ms]
r9749[0...63] SI message value / SI msg_value
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Integer32 Dynamic index: - Func. diagram: -
P-Group: Messages Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -