Parameters
List of parameters
1-110
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the properties supported by the Voltage Sensing Module (VSM).
Description: Displays the version of loader 1 (first level loader).
Dependency: Refer to: r0018, r0128, r0148, r0158, r0198
Note: Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description: Displays the version of loader 2 (second level loader).
Dependency: Refer to: r0018, r0128, r0148, r0158, r0197
Note: Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description: Freely assignable name for a drive object.
In the commissioning software, this name cannot be entered using the expert list, but is specified in the configura-
tion assistant. The object name can be subsequently modified in the Project Navigator using standard Windows
resources.
r0194[0...n] VSM properties / VSM properties
A_INF, S_INF, VEC-
TOR
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned32 Dynamic index: p0140 Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Reserved Yes No -
r0197 Loader 1 version / Loader 1 version
CU_CX32, CU_S Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r0198 Loader 2 version / Loader 2 version
CU_CX32, CU_S Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
p0199[0...24] Drive object name / DO name
All objects Can be changed: C1 Calculated: - Access level: 2
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 65535 0