Parameters
List of parameters
1-50
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note: Smoothing time constant = 300 ms
The signal is not suitable as process quantity and may only be used as display quantity.
The active current actual value is available smoothed (r0030) and unsmoothed (r0078).
Description: Displays the smoothed torque-generating actual current.
Dependency: Refer to: r0078
Note: SERVO: Smoothing time constant = 100 ms
VECTOR: Smoothing time constant = 300 ms
The signal is not suitable as process quantity and may only be used as display quantity.
The following applies for SERVO:
The torque-generating current actual value is available smoothed (r0030 with 100 ms, r0078[1] with p0045) and
unsmoothed (r0078[0]).
For VECTOR, the following applies:
The torque-generating current actual value is available smoothed (r0030 with 300 ms) and unsmoothed (r0078).
Description: Displays the smoothed force-generating actual current.
Dependency: Refer to: r0078
Note: SERVO: Smoothing time constant = 100 ms
VECTOR: Smoothing time constant = 300 ms
The signal is not suitable as process quantity and may only be used as display quantity.
The following applies for SERVO:
The force-generating current actual value is available smoothed (r0030 with 100 ms, r0078[1] with p0045) and
unsmoothed (r0078[0]).
For VECTOR, the following applies:
The torque-generating current actual value is available smoothed (r0030 with 300 ms) and unsmoothed (r0078).
Description: Displays the smoothed torque actual value.
Dependency: Refer to: r0080
Note: Smoothing time constant = 100 ms
The signal is not suitable as process quantity and may only be used as display quantity.
The active current actual value is available smoothed (r0031) and unsmoothed (r0080).
r0030 Current actual value, torque-generating smoothed / Iq_act smooth
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 5730, 6799
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r0030 Current actual value force generating smoothed / Iq_act smooth
SERVO (Lin) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 5730, 6799
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r0031 Actual torque smoothed / M_act smooth
SERVO, VECTOR Can be changed: - Calculated: - Access level: 2
Data type: Floating Point Dynamic index: - Func. diagram: 5730, 6799
P-Group: Displays, signals Units group: 7_2 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting