EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-154 5050 - Kp_n;Tn_n adaptation

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Diagrams
Servo control
2-1272
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-154 5050 – Kp_n/Tn_n adaptation
- 5050 -
Function diagram
87654321
fp_5050_01_eng.vsd
DO: SERVO
SINAMICS SServo control - Kp_n/Tn_n adaptation
Free Kp_n adaptation
Adapt_factor upper
0.0...200 000.0 [%]
p1459[D] (100.0)
[5040.8]
0.00...210 000.00 [RPM]
p1465[D] (0.00)
Speed-dependent Kp_n/Tn_n adaptation
Tn_n_adapt
Kp_n_basic (p1460)
y
x
Tn
r0063
n_act smooth
[4710.6]
p1461[D] (100 %)
Kp
n
Kp
0.00...210 000.00 [RPM]
p1464[D] (0.00)
Kp_n_adapt
To the speed controller with encoder
[5040.4]
To the speed controller without encoder
[5210.3]
1.00 with factory setting
0.00...400.00 [%]
p1456[D] (0.00)
0.00...400.00 [%]
p1457[D] (0.00)
n_ctrl Kp scal
(1)
p1466[C]
n_ctrl Adpt_sig Kp
(0)
p1455[C]
Adapt_factor lower
0.0...200 000.0 [%]
p1458[D] (100.0)
referred to p200x
x
n
1000.00 µs
Tn
n
15.05.07 V02.05.00
p1463[D] (100 %)
[5040.8]
n
Tn_n_basic (p1462)
Kp_n adaptation factor

Table of Contents