Faults and Alarms
List of faults and alarms
3-1724
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
F35053 TM54F: Temperature fault threshold exceeded
Drive object: A_INF, B_INF, CU_LINK, DMC20, SERVO, S_INF, TB30, TM15, TM15DI_DO, TM17, TM31, TM41, TM54F_MA,
TM54F_SL, VECTOR
Reaction: NONE
Acknowledge: IMMEDIATELY (POWER ON)
Cause: The temperature measured using the temperature sensing on the TM54F has exceeded the threshold value to ini-
tiate this fault.
As fault response, instead of the fail-safe input image, a logical 0 signal is transferred to the motion monitoring func-
tion.
Fault value (r0949, interpret decimal):
Only for internal Siemens troubleshooting.
Remedy: - allow the TM54F to cool down.
- carry out a POWER ON.
A35075 (F) TM54F: Internal communications
Drive object: A_INF, B_INF, CU_LINK, DMC20, SERVO, S_INF, TB30, TM15, TM15DI_DO, TM17, TM31, TM41, TM54F_MA,
TM54F_SL, VECTOR
Reaction: NONE
Acknowledge: NONE
Cause: An internal communications error has occurred in the Terminal Module 54F (TM54F).
Fault value (r0949, interpret decimal):
Only for internal Siemens diagnostics.
Remedy: - check the electrical cabinet design and cable routing for EMC compliance
- upgrade the software on the TM54F.
- contact the Hotline.
- replace the TM54F.
Reaction upon F: NONE
Acknowl. upon F: IMMEDIATELY (POWER ON)
A35080 (F) TM54F: Checksum error safety parameters
Drive object: A_INF, B_INF, CU_LINK, DMC20, SERVO, S_INF, TB30, TM15, TM15DI_DO, TM17, TM31, TM41, TM54F_MA,
TM54F_SL, VECTOR
Reaction: NONE
Acknowledge: NONE
Cause: The calculated checksum entered in r10004 over the safety-relevant parameters does not match the reference
checksum saved in p10005 at the last machine acceptance.
Fault value (r0949, interpret decimal):
1: Checksum error for functional SI parameters.
2: Checksum error for SI parameters for component assignment.
Remedy: - Check the safety-relevant parameters and if required, correct.
- set the reference checksum to the actual checksum.
- acknowledge that hardware was replaced
- carry out a POWER ON.
- carry out an acceptance test.
Reaction upon F: NONE
Acknowl. upon F: IMMEDIATELY (POWER ON)
F35150 TM54F: Communication error
Drive object: A_INF, B_INF, CU_LINK, DMC20, SERVO, S_INF, TB30, TM15, TM15DI_DO, TM17, TM31, TM41, TM54F_MA,
TM54F_SL, VECTOR
Reaction: NONE
Acknowledge: IMMEDIATELY (POWER ON)
Cause: A communication error between the TM54F master and Control Unit or between the TM54F slave and the Motor
Module was detected.
Fault value (r0949, interpret hexadecimal):
Only for internal Siemens troubleshooting.