List of parameters
Parameters
1-219
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the constant kT7 for the torque characteristic:
kT(iq)=kT1+kT3*iq^2+kT5*iq^4+kT7*iq^6
Dependency: Refer to: p0645, p0646, p0647
Description: Displays the operating hours for the corresponding motor.
The motor operating time counter continues to run when the pulses are enabled. When the pulse enable is with-
drawn, the counter is held and the value saved.
Dependency: The following prerequisites must be fulfilled in order to be able to save the operating hours counter in a non-volatile
fashion:
- firmware with V2.2 or higher.
- Control Unit 320 (CU320) with hardware version C or higher (module with NVRAM).
Refer to: p0651
Refer to: A01590
Note: The operating hours counter in p0650 can only be reset to 0. In this case, p0651 is automatically set to 0.
For p0651 = 0, the operating hours counter is disabled.
The operating hours counter only runs for MDS0 and MDS1 (Motor Data Set).
Description: Sets the service/maintenance intervals in hours for the appropriate motor.
An appropriate fault is output when the operating hourse set here are reached.
Dependency: Refer to: p0650
Refer to: A01590
Note: For p0651 = 0, the operating hours counter is disabled.
The operating hours counter only runs for MDS0 and MDS1 (Motor Data Set).
p0648[0...n] Motor-torque characteristic kT7 / Mot kT7
SERVO (Exp M_ctrl) Can be changed: C2(1, 3), U, T Calculated: - Access level: 1
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, REL, FEM Expert list: 1
Min Max Factory setting
- - -
p0650[0...n] Actual motor operating hours / Mot t_oper act
SERVO, VECTOR Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 [h] 4294967295 [h] 0 [h]
p0651[0...n] Motor operating hours maintenance interval / Mot t_op maint
SERVO, VECTOR Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 [h] 99999 [h] 0 [h]