Description: Sets the velocity limit for the SSM feedback signal (n < n_x) to detect standstill.
When this limit value is fallen below, the signal "SSM feedback signal active" (SGA n < n_x) is set.
Caution: The function "Safe Acceleration Monitor" (SBR) is switched-out after the selected threshold value is fallen below.
Note: A change only becomes effective after a POWER ON.
F-DO: Failsafe Digital Output / SGA: Safety-related output
SBR: Safe Acceleration Monitor
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring) / SGA n < nx: Safety-
related output n < nx
Description: Sets the velocity limit for the SSM feedback signal (n < n_x) to detect standstill.
When this limit value is fallen below, the signal "SSM feedback signal active" (SGA n < n_x) is set.
Caution: The function "Safe Acceleration Monitor" (SBR) is switched-out after the selected threshold value is fallen below.
Note: A change only becomes effective after a POWER ON.
F-DO: Failsafe Digital Output / SGA: Safety-related output
SBR: Safe Acceleration Monitor
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring) / SGA n < nx: Safety-
related output n < nx
Description: Sets the velocity tolerance for the "Safe Acceleration Monitor".
Dependency: Refer to: C01706
Note: A change only becomes effective after a POWER ON.
SBR: Safe Acceleration Monitor
p9546 SI motion SSM (SGA n < nx) velocity limit n_x (CU) / SI Mtn SSM v_limCU
SERVO, VECTOR Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [mm/min] 1000000.00 [mm/min] 20.00 [mm/min]
p9546 SI motion SSM (SGA n < nx) velocity limit n_x (CU) / SI Mtn SSM v_limCU
SERVO (Safety rot),
VECTOR (Safety rot)
Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [RPM] 1000000.00 [RPM] 20.00 [RPM]
p9548 SI motion SBR actual velocity tolerance (Control Unit) / SI Mtn SBR tol
SERVO, VECTOR Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [mm/min] 120000.00 [mm/min] 300.00 [mm/min]