Parameters
List of parameters
1-630
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency: Refer to: r2521, r2522, r2523
Note: Re bit 04:
The signal is influenced via p2634.
Re bit 05:
The signal is influenced via p2635.
Description: Displays the status word of the position actual value sensing for encoder 1.
Description: Displays the status word of the position actual value sensing for encoder 2.
Description: Displays the status word of the position actual value sensing for encoder 3.
05 Fixed stop outside window Yes No 3617
06 Position controller output limited Yes No 4015
07 Request tracking mode Yes No -
08 Clamping active when traveling to fixed stop Yes No -
09 Setting value for adjustment valid Yes No -
r2527.0...2 CO/BO: LR actual value sensing status word encoder 1 / ActValSensZSW enc1
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed: - Calculated: - Access level: 1
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Closed loop position control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Pos act val valid Yes No -
01 Referencing active Yes No -
02 Meas val valid Yes No -
r2528.0...2 CO/BO: LR actual value sensing status word encoder 2 / ActValSensZSW enc2
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed: - Calculated: - Access level: 1
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Closed loop position control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Pos act val valid Yes No -
01 Referencing active Yes No -
02 Meas val valid Yes No -
r2529.0...2 CO/BO: LR actual value sensing status word encoder 3 / ActValSensZSW enc3
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed: - Calculated: - Access level: 1
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Closed loop position control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Pos act val valid Yes No -
01 Referencing active Yes No -
02 Meas val valid Yes No -