List of parameters
Parameters
1-675
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the actual position for the following events:
- external block change via measuring probe (p2632 = 0, BI: p2661 = 0/1 signal).
- external block change via BI: p2633 (p2632 = 1, BI: p2633 = 0/1 signal).
- activate traversing task (BI: p2631 = 0/1 signal).
Dependency: Refer to: p2631, p2632, p2633, p2661
Description: Displays the clearance determined between the reference cam and zero mark in the search for reference.
Description: Displays the currently effective velocity override.
Dependency: Refer to: p2571, p2646
Note: The effective override can differ from the specified override due to limits (e.g. p2571, maximum velocity).
Description: Displays the actual residual distance.
The remaining distance is the distance to still to be moved through up to the end of the current positioning task.
Dependency: Refer to: r2665, r2671, r2678
r2678 CO: EPOS external block change / Ext BlckChg s_act
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: - Calculated: - Access level: 1
Data type: Integer32 Dynamic index: - Func. diagram: 3615, 3616,
3620
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [LU] - [LU] - [LU]
r2680 CO: EPOS clearance, reference cam and zero mark / Clearance cam/ZM
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: - Calculated: - Access level: 1
Data type: Integer32 Dynamic index: - Func. diagram: 3612
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [LU] - [LU] - [LU]
r2681 CO: EPOS velocity override effective / v_over effective
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: - Calculated: - Access level: 1
Data type: Floating Point Dynamic index: - Func. diagram: 3630
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r2682 CO: EPOS residual distance to go / Residual distance
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: - Calculated: - Access level: 1
Data type: Integer32 Dynamic index: - Func. diagram: 3635
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [LU] - [LU] - [LU]