List of parameters
Parameters
1-993
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the number of signal drains of this drive object to other drives/drive objects that are no longer opera-
tional/de-activated (Binector Input/Connector Input, BI/CI).
Dependency: Refer to: p9495, p9496, r9498, r9499
Refer to: A01318, A01507
Note: The parameter is only used for display purposes and cannot be written into.
Description: List of the BI/CI parameters that represent a connection to non-operational/de-activated drive objects.
Dependency: Refer to: p9495, p9496, p9497, r9499
Refer to: A01318, A01507
Note: All indices from r9498 to r9499 designate the same BICO interconnection.
This signal drain is in r9498[x] and the associated signal source in r9499[x].
Description: List of the BO/CO parameters that represent a connection to non-operational/de-activated drive objects.
Dependency: Refer to: p9495, p9496, p9497, r9498
Refer to: A01318, A01507
Note: All indices from r9498 to r9499 designate the same BICO interconnection.
This signal drain is in r9498[x] and the associated signal source in r9499[x].
p9497 BICO number of interconnections to de-activated drive objects / Qty to deact obj
A_INF, B_INF,
CU_CX32, CU_LINK,
CU_S, SERVO,
TB30, TM15,
TM15DI_DO, TM17,
TM31, TM41, VEC-
TOR
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 65535 0
r9498[0...29] BICO BI/CI parameters to de-activated drive objects / BI/CI to deact obj
A_INF, B_INF,
CU_CX32, CU_LINK,
CU_S, SERVO,
TB30, TM15,
TM15DI_DO, TM17,
TM31, TM41, VEC-
TOR
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r9499[0...29] BICO BO/CO parameters to de-activated drive objects / BO/CO to deact obj
A_INF, B_INF,
CU_CX32, CU_LINK,
CU_S, SERVO,
TB30, TM15,
TM15DI_DO, TM17,
TM31, TM41, VEC-
TOR
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -