EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-284 9951 - Sequencer (r0108.26 = 1)

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Braking Module external
Function Diagrams
2-1421
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-284 9951 – Sequencer (r0108.26 = 1)
- 9951 -
Function diagram
87654321
fp_9951_01_eng.vsd
DO: A_INF, B_INF, S_INF
SINAMICS S
21.03.07 V02.05.00
Braking Module External - Sequence Control (r0108.26 = 1)
r0108.26 (4000.00 µs)
Braking Module External
[2130]...[2133]
[2130]...[2133]
S1: Ready
S2: Fault
A06900
“Fault (1 -> 0)“
S4: Alarm
A06901
"Pre-alarm I
2
t shutdown“
S3: DC link fast discharge
1
T
p3862
0
&
Inhibit/acknowledgement Braking Module 1
r3861.0
Fast discharge Braking Module 1
r3864.0
BM I
2
t shutdown
p3865[0]
BM fault
p3866[0]
[2120]...[2133]
r0899.11 "Pre-charging compl"
r0863.1 "Engergize contactor"
&
BM DC-dischg act
p3863
&
&
&
&
&
&
[2120]...[2133]
DO
DI
DI
DO
BM qty par_cct
1...8
p3860 (1)
X21.1
X21.2
X21.3
X21.4
X1 R1
X1 R2
X21.5
X21.6
Ground
Ground

Table of Contents