Parameters
List of parameters
1-164
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the damping resistance of the separately-excited synchronous motor quadrature to the rotor direction (q
axis).
Description: Displays the rated (nominal) rotor/secondary section resistance of the motor at the rated temperature (sum of
p0625 and p0628).
Dependency: Refer to: p0628
Note: The parameter is not used for synchronous motors (p0300 = 2xx).
Description: Induction motor, separately-excited synchronous motor:
Displays the stator leakage inductance of the motor including the series inductance (p0353) for servo drives and the
motor reactor (p0233) for vector drives.
Synchronous motor:
Displays the stator quadrature axis inductance including the series inductance (p0353) for servo drives and the
motor reactor (p0233) for vector drives.
Description: Displays the stator longitudinal inductance of the synchronous motor including the series inductance (p0353) and
the motor reactor (p0233).
Note: The parameter is not used for separately-excited synchronous motors (p0300 = 5).
r0375[0...n] Motor damping resistance, q axis / Mot R_damp q
VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 16_1 Unit selection: p0349
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
- [Ohm] - [Ohm] - [Ohm]
r0376[0...n] Rated motor rotor resistance / Mot R_rotor rated
SERVO, VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 16_1 Unit selection: p0349
Not for motor type: PEM, REL, FEM Expert list: 1
Min Max Factory setting
- [Ohm] - [Ohm] - [Ohm]
r0377[0...n] Motor leakage inductance, total / Mot L_leak total
SERVO, VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: 6640
P-Group: Motor Units group: 15_1 Unit selection: p0349
Not for motor type: - Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]
r0378[0...n] Motor stator inductance, d axis / Mot L_stator_d
VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 15_1 Unit selection: p0349
Not for motor type: ASM, REL, FEM Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]