Siemens SINAMICS S Series - p1040[0...n] Motorized potentiometer starting value; Mop start value; p1041[0...n] BI: Motorized potentiometer manual;automatic; Mop manual;auto; p1042[0...n] CI: Motorized potentiometer automatic setpoint; Mop auto setpoint; p1043[0...n] BI: Motorized potentiometer accept setpoint; Mop accept set val

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-303
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the starting value for the motorized potentiometer. This starting value becomes effective after the drive has
been powered-up.
Dependency: Only effective if p1030.0 = 0.
Refer to: p1030
Description: Sets the signal source to change over from manual to automatic when using a motorized potentiometer.
In the manual mode, the setpoint is changed using two signals - raise and lower. In the automatic mode, the set-
point must be interconnected via a connector input.
Dependency: Refer to: p1030, p1035, p1036, p1042
Note: The effectiveness of the internal ramp-function generator can be set in automatic mode.
Description: Sets the signal source for the setpoint of the motorized potentiometer in the automatic mode.
Dependency: Refer to: p1041
Description: Sets the signal source for the setting command to accept the setting value for the motorized potentiometer.
Dependency: Refer to: p1044
p1040[0...n] Motorized potentiometer starting value / Mop start value
SERVO (Extended
setp, Lin)
Can be changed: U, T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 3020
P-Group: Setpoints Units group: 4_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
-1000.000 [m/min] 1000.000 [m/min] 0.000 [m/min]
p1041[0...n] BI: Motorized potentiometer manual/automatic / Mop manual/auto
SERVO (Extended
setp), VECTOR
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: CDS, p0170 Func. diagram: 3020
P-Group: Setpoints Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p1042[0...n] CI: Motorized potentiometer automatic setpoint / Mop auto setpoint
SERVO (Extended
setp), VECTOR
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 3020
P-Group: Setpoints Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p1043[0...n] BI: Motorized potentiometer accept setpoint / Mop accept set val
SERVO (Extended
setp), VECTOR
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: CDS, p0170 Func. diagram: 3020
P-Group: Setpoints Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0