Siemens SINAMICS S Series - r9733[0...1] CO: SI Motion effective setpoint speed limiting; SI Mtn setp limit; r9735[0...1] SI motion diagnostics result list 3; SI Mtn res_list 3

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-1026
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Index: [0] = Checksum over SI parameters for motion monitoring
[1] = Checksum over SI parameters for actual values
Dependency: Refer to: r9728
Refer to: F01680
Description: Displays the necessary setpoint speed limit as a result of the selected SI motion monitoring functions.
Contrary to the parameterization of the SI limit values, this parameter specifies the motor-side limit value and not
the load-side limit value.
Index: [0] = Setpoint limiting positive
[1] = Setpoint limiting negative
Dependency: r9733[0] = p9531[x] * p9533; x = selected SLS stage
r9733[1] = - p9531[x] * p9533; x = selected SLS stage
Refer to: p9531, p9533
Notice: If r9733[0] is interconnected to p1085, then r9733[1] must also be interconnected to p1088.
If only the absolute value of the setpoint velocity limiting is required, r9733[0] is sufficient.
Note: The units changeover between linear and rotary axis units is not realized via the safety changeover (p9502), but by
the linear motor changeover.
Description: Displays the necessary setpoint speed limit as a result of the selected SI motion monitoring functions.
Contrary to the parameterization of the SI limit values, this parameter specifies the motor-side limit value and not
the load-side limit value.
Index: [0] = Setpoint limiting positive
[1] = Setpoint limiting negative
Dependency: r9733[0] = p9531[x] * p9533; x = selected SLS stage
r9733[1] = - p9531[x] * p9533; x = selected SLS stage
Refer to: p9531, p9533
Notice: If r9733[0] is interconnected to p1085, then r9733[1] must also be interconnected to p1088.
If only the absolute value of the setpoint velocity limiting is required, r9733[0] is sufficient.
Note: The units changeover between linear and rotary axis units is not realized via the safety changeover (p9502), but by
the linear motor changeover.
Description: Displays result list 3, that for the data cross-check with the control, led to the fault.
r9733[0...1] CO: SI Motion effective setpoint speed limiting / SI Mtn setp limit
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: 3_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [RPM] - [RPM] - [RPM]
r9733[0...1] CO: SI Motion effective setpoint speed limiting / SI Mtn setp limit
SERVO (Lin) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: 4_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [m/min] - [m/min] - [m/min]
r9735[0...1] SI motion diagnostics result list 3 / SI Mtn res_list 3
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -