Parameters
List of parameters
1-1050
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Selects an input terminal (input terminal of the Control Unit or a Terminal Module) to start the test stop.
The test stop is started with a 0/1 signal at the input terminal and is then only possible if the TM54F is not in the
commissioning mode (p0010 = 0).
Dependency: Refer to: p10001, p10003, p10041, p10046
Notice: It is not permissible to use an input on the TM54F to start the test stop.
Description: Sets the operating mode for the Terminal Module 54F (TM54F).
Values: 0: Function interface
1: Control interface
Note: Parameter is being prepared - for this firmware version, the function interface is not supported.
Description: Sets the drive object number for the drives that are available.
Index: [0] = Drive 1
[1] = Drive 2
[2] = Drive 3
[3] = Drive 4
[4] = Drive 5
[5] = Drive 6
Notice: If, for a drive, safety with TM54F is activated (p9601 = 5), then its drive object number must be precisely entered
into one index of p10010.
Description: Sets the drive group for the drives that are available.
A drive group is a combination of several drives with the same types of behavior.
p10007 BI: SI input terminal forced checking procedure F-DO 0 ... 3 / SI DI fcp F-DO
TM54F_MA Can be changed: C2 Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 2848
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p10008 SI operating mode TM54F / SI op_mode TM54F
TM54F_MA,
TM54F_SL
Can be changed: C2 Calculated: - Access level: 4
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 1
p10010[0...5] SI drive object assignment / SI drv_obj assign
TM54F_MA,
TM54F_SL
Can be changed: C2 Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: 2846, 2848
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 32 0
p10011[0...5] SI drive group assignment / SI drv_gr assign
TM54F_MA,
TM54F_SL
Can be changed: C2 Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: 2848
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
1 4 1