List of parameters
Parameters
1-893
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: For the particular Motor Module, the correction time must be added to the valve lockout time to be compensated for
phase W (p1830).
The corrective value is used to compensate variations/spread in the valve lockout times of Motor Modules for a par-
allel circuit configuration.
Dependency: Refer to: p1830
Description: Displays the circulating current of phase U as peak value.
Description: Displays the circulating current of phase V as peak value.
Description: Displays the circulating current of phase W as peak value.
Description: Ring buffer for faults and alarms that have occurred from power units connected in parallel (Motor Module, Active
Line Infeed, Voltage Sensing Module).
Displays the fault/alarm code.
p7044[0...n] Par_circuit correction valve lockout time phase W / Comp t_lockout W
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed: U, T Calculated: - Access level: 4
Data type: Floating Point Dynamic index: PDS, p0120 Func. diagram: -
P-Group: Modulation Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [µs] 1000000.00 [µs] 0.00 [µs]
r7050[0...n] Par_circuit circulating current phase U / Circ_I_phase U
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 6_5 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7051[0...n] Par_circuit circulating current phase V / Circ_I_phase V
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 6_5 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7052[0...n] Par_circuit circulating current phase W / Circ_I_phase W
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 6_5 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7100[0...99] Par_circuit ring buffer fault/alarm code / Fault/alarm code
A_INF (Parallel),
B_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -