Siemens SINAMICS S Series - p7044[0...n] Par_circuit correction valve lockout time phase W; Comp t_lockout W; r7050[0...n] Par_circuit circulating current phase U; Circ_I_phase U; r7051[0...n] Par_circuit circulating current phase V; Circ_I_phase V; r7052[0...n] Par_circuit circulating current phase W; Circ_I_phase W

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-893
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: For the particular Motor Module, the correction time must be added to the valve lockout time to be compensated for
phase W (p1830).
The corrective value is used to compensate variations/spread in the valve lockout times of Motor Modules for a par-
allel circuit configuration.
Dependency: Refer to: p1830
Description: Displays the circulating current of phase U as peak value.
Description: Displays the circulating current of phase V as peak value.
Description: Displays the circulating current of phase W as peak value.
Description: Ring buffer for faults and alarms that have occurred from power units connected in parallel (Motor Module, Active
Line Infeed, Voltage Sensing Module).
Displays the fault/alarm code.
p7044[0...n] Par_circuit correction valve lockout time phase W / Comp t_lockout W
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed: U, T Calculated: - Access level: 4
Data type: Floating Point Dynamic index: PDS, p0120 Func. diagram: -
P-Group: Modulation Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [µs] 1000000.00 [µs] 0.00 [µs]
r7050[0...n] Par_circuit circulating current phase U / Circ_I_phase U
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 6_5 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7051[0...n] Par_circuit circulating current phase V / Circ_I_phase V
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 6_5 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7052[0...n] Par_circuit circulating current phase W / Circ_I_phase W
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 6_5 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7100[0...99] Par_circuit ring buffer fault/alarm code / Fault/alarm code
A_INF (Parallel),
B_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -