Parameters
List of parameters
1-926
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the signal source for the wordwise data transfer (process signal).
This signal value is transferred to another Control Unit and is located in CO: r8513 for further interconnection.
Dependency: Refer to: r8513
Description: Sets the signal source for the wordwise data transfer (process signal).
This signal value is transferred to another Control Unit and is located in CO: r8514 for further interconnection.
Dependency: Refer to: r8514
Description: Sets the signal source for the wordwise data transfer (process signal).
This signal value is transferred to another Control Unit and is located in CO: r8515 for further interconnection.
Dependency: Refer to: r8515
Description: Displays the signals of the bitwise received data.
These signals were interconnected and transferred to another Control Unit via BI: p8500[0...7].
p8503 CI: Data transfer 1 wordwise / Transfer 1 word
CU_CX32, CU_LINK Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dynamic index: - Func. diagram: 2211
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p8504 CI: Data transfer 2 wordwise / Transfer 2 word
CU_CX32, CU_LINK Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dynamic index: - Func. diagram: 2211
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p8505 CI: Data transfer 3 wordwise / Transfer 3 word
CU_CX32, CU_LINK Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dynamic index: - Func. diagram: 2211
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
r8510.0...7 BO: Data transfer 0 receive bitwise / Trans 0 recv bit
CU_CX32, CU_LINK Can be changed: - Calculated: - Access level: 2
Data type: Unsigned32 Dynamic index: - Func. diagram: 2211
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Receive signal from BI: p8500 On Off -
01 Receive signal from BI: p8500 On Off -
02 Receive signal from BI: p8500 On Off -
03 Receive signal from BI: p8500 On Off -
04 Receive signal from BI: p8500 On Off -
05 Receive signal from BI: p8500 On Off -
06 Receive signal from BI: p8500 On Off -
07 Receive signal from BI: p8500 On Off -