Parameters
List of parameters
1-1012
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the transition time from STOP F to STOP B.
Dependency: Refer to: C01711
Note: A change only becomes effective after a POWER ON.
Description: Sets the delay time for the safe pulse cancelation after STOP B.
Dependency: Refer to: p9560
Refer to: C01701
Note: A change only becomes effective after a POWER ON.
Description: Sets the time after which the pulses must have been canceled when initiating the test stop.
Dependency: Refer to: C01798
Note: A change only becomes effective after a POWER ON.
Description: Sets the maximum time for the acceptance test mode.
If the acceptance test mode takes longer than the selected time limit, then the mode is automatically terminated.
Dependency: Refer to: C01799
Note: A change only becomes effective after a POWER ON.
p9555 SI motion transition time STOP F to STOP B (Control Unit) / SI Mtn t F->B CU
SERVO, VECTOR Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 2825
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [ms] 600000.00 [ms] 0.00 [ms]
p9556 SI motion pulse cancelation delay time (Control Unit) / SI Mtn IL t_del CU
SERVO, VECTOR Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 2825
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [ms] 600000.00 [ms] 100.00 [ms]
p9557 SI motion pulse cancelation test time (Control Unit) / SI Mtn IL t_test
SERVO, VECTOR Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [ms] 10000.00 [ms] 100.00 [ms]
p9558 SI motion acceptance test mode time limit (Control Unit) / SI Mtn t accept
SERVO, VECTOR Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
5000.00 [ms] 100000.00 [ms] 40000.00 [ms]