Siemens SINAMICS S Series - p9555 SI motion transition time STOP F to STOP B (Control Unit); SI Mtn t F�>B CU; p9556 SI motion pulse cancelation delay time (Control Unit); SI Mtn IL t_del CU; p9557 SI motion pulse cancelation test time (Control Unit); SI Mtn IL t_test; p9558 SI motion acceptance test mode time limit (Control Unit); SI Mtn t accept

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-1012
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the transition time from STOP F to STOP B.
Dependency: Refer to: C01711
Note: A change only becomes effective after a POWER ON.
Description: Sets the delay time for the safe pulse cancelation after STOP B.
Dependency: Refer to: p9560
Refer to: C01701
Note: A change only becomes effective after a POWER ON.
Description: Sets the time after which the pulses must have been canceled when initiating the test stop.
Dependency: Refer to: C01798
Note: A change only becomes effective after a POWER ON.
Description: Sets the maximum time for the acceptance test mode.
If the acceptance test mode takes longer than the selected time limit, then the mode is automatically terminated.
Dependency: Refer to: C01799
Note: A change only becomes effective after a POWER ON.
p9555 SI motion transition time STOP F to STOP B (Control Unit) / SI Mtn t F->B CU
SERVO, VECTOR Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 2825
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [ms] 600000.00 [ms] 0.00 [ms]
p9556 SI motion pulse cancelation delay time (Control Unit) / SI Mtn IL t_del CU
SERVO, VECTOR Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 2825
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [ms] 600000.00 [ms] 100.00 [ms]
p9557 SI motion pulse cancelation test time (Control Unit) / SI Mtn IL t_test
SERVO, VECTOR Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [ms] 10000.00 [ms] 100.00 [ms]
p9558 SI motion acceptance test mode time limit (Control Unit) / SI Mtn t accept
SERVO, VECTOR Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
5000.00 [ms] 100000.00 [ms] 40000.00 [ms]