List of parameters
Parameters
1-73
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the reactive current actual value.
Dependency: Refer to: r0029
Note: The reactive current actual value is available smoothed (r0029) and unsmoothed (r0076).
Description: Displays the field-generating current actual value (Id_act).
Dependency: Refer to: r0029
Note: This value is irrelevant for the V/f control mode.
The field-generating current actual value is available smoothed (r0029) and unsmoothed (r0076).
Description: Displays the active current setpoint (Iq_set).
Description: Displays the torque/force generating current setpoint.
Note: This value is irrelevant for the V/f control mode.
r0076 CO: Reactive current actual value / I_reactive_act
A_INF, S_INF Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1774, 1775,
8850, 8946, 8950
P-Group: Displays, signals Units group: 6_2 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r0076 CO: Current actual value, field-generating / Id_act
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1630, 1710,
5714, 5730, 6714, 6799
P-Group: Displays, signals Units group: 6_2 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r0077 CO: Active current setpoint / Iq_set
A_INF Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1774, 8940,
8946
P-Group: Displays, signals Units group: 6_2 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r0077 CO: Current setpoint, torque-generating / Iq_set
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1630, 1774,
5714, 6710, 6714, 6719
P-Group: Displays, signals Units group: 6_2 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]