List of parameters
Parameters
1-89
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the activated function module for the particular drive object.
Note: A "function module" is a functional expansion of a drive object that can be activated when commissioning.
Description: Displays the activated function module for the particular drive object.
Note: A "function module" is a functional expansion of a drive object that can be activated when commissioning.
r0108 Drive object, function module / DO function module
SERVO Can be changed: - Calculated: - Access level: 2
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
01 Expanded closed-loop torque control Activated Not activated -
03 Closed-loop position control Activated Not activated -
04 Basic positioner Activated Not activated -
07 Advanced Positioning Control (APC) Activated Not activated -
08 Extended setpoint channel Activated Not activated -
12 Linear motor Activated Not activated -
13 Safety rotary axis Activated Not activated -
14 Extended brake control Activated Not activated -
16 Techn controller Activated Not activated -
17 Extended messages/monitoring Activated Not activated -
18 Free function blocks Activated Not activated -
28 Cooling system Activated Not activated -
29 CAN Activated Not activated -
31 PROFINET Activated Not activated -
r0108 Drive object, function module / DO function module
VECTOR Can be changed: - Calculated: - Access level: 2
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
02 Closed-loop speed/torque control Activated Not activated -
03 Closed-loop position control Activated Not activated -
04 Basic positioner Activated Not activated -
13 Safety rotary axis Activated Not activated -
14 Extended brake control Activated Not activated -
15 Parallel cct. config. Activated Not activated -
16 Technology controller Activated Not activated -
17 Extended messages/monitoring Activated Not activated -
18 Free function blocks Activated Not activated -
28 Cooling system Activated Not activated -
29 CAN Activated Not activated -
31 PROFINET Activated Not activated -