EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-176 6320 - Vdc_max controller and Vdc_min controller

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Vector control
Function Diagrams
2-1295
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-176 6320 – Vdc_max controller and Vdc_min controller
- 6320 -
Function diagram
87654321
fp_6320_01_eng.vsd
DO: VECTOR
SINAMICS S
19.02.07 V02.05.00
Vector control - Vdc_max controller and Vdc_min controller
[8950.1]
r0070
Vdc_act
Vdc_ctrl output_limit
p1293
0
Control ZSW 1
r0056.14
r0056
0
1
Vdc_ctrl Kp
p1290
Vdc_ctrl Tn
p1291
Vdc_ctrl t_deriv action
p1292
Vdc_max dyn_factor
p1283
Vdc_ctrl config.
p1280
0,2,4,5,6
1,3
Vdc_max (V/f)
Vdc_min (V/f)
Vdc_max on_level
r1282
+
0
- Vdc_ctrl output_limit
p1293
Control ZSW 1
r0056.15
r0056
0
1
Vdc_ctrl output
r1298
Vdc_ctrl Kp
p1290
Vdc_ctrl Tn
p1291
Vdc_ctrl t_deriv action
p1292
Vdc_min dyn_factor
p1287
Vdc_ctrl config
p1280
[8950.1]
r0070
Vdc_act
Vdc_min on_level
r1286
+
0 [1690]
0
0
0,1,4,5,6
2,3
[2526.2]
[2526.2]
Refer to [1020.7]
p0115[y] (Motor Modules)
0
0
Vdc_max SenseOnLev
p1254
Supply voltage
p0210
Vdc_min on_level
p1245
Calculate on_level
Calculate on_level
<1> p1280
[0] Inhib Vdc ctrl
[1] Enables Vdc_max controller
[2] Enables Vdc_min controller (kinetic buffering)
[3] Enables Vdc_min controller and Vdc_max controller
[4] Activates Vdc_max monitoring
[5] Activates Vdc_min monitoring
[6] Activates Vdc_min monitoring and Vdc_max monitoring
<1>
<1>

Table of Contents

Related product manuals