Siemens SINAMICS S Series - Figure 2-275 9678 - Control word sequence control

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Diagrams
Terminal Module 41 (TM41)
2-1408
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-275 9678 – Control word sequence control
- 9678 -
Function diagram
87654321
fp_9678_51_eng.vsd
DO: TM41
SINAMICS
27.07.07 V02.05.00
Terminal Module 41 (TM41) - Control word, sequence control (p4400 = 0)
p0844[C]
(1)
1 OFF2 (electrical)
p0845[C]
(1)
2 OFF2 (electrical)
p0848[C]
(1)
1 OFF3 (Fstop)
p0849[C]
(1)
2 OFF3 (Fstop)
11
12
13
14
15
p0840[C]
(0)
AUS1
p0852[C]
(1)
p1140[C]
(1)
p1141[C]
(1)
p1142[C]
(1)
PROFIdrive-Bit
10
7
6
5
4
3
2
1
0
Bit Nr.
<1>
<1>
<1> PROFIdrive interconnection:
For PROFIdrive standard telegrams, the upper inputs are
connected to the PROFIdrive-STW1 [2420].
Only applies for CDS0.
2000.00 µs
r0898.0
r0898.1
r0898.2
r0898.3
r0898.4
r0898.5
r0898.6
r0898
STW seq_ctrl
r0898.7
9
8
Control word sequence control
1 = Operating condition no coast down active (OFF2 inactive)
0 = OFF2 active
1 = Operating condition no fast stop active (OFF3 inactive)
0 = OFF3 active
1 = Acknowledge fault
Reserved
1 = Enable zero mark
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
= ON
0 = OFF1 active
1 = Start ramp-up generator
0 = Freeze ramp-up generator
1 = Enable ramp-function generator
1 = Enable speed setpoint
1 = Enable operation
r0898.13p4401 [9674.8][9676.8]
p2103[C]
(0)