List of parameters
Parameters
1-1067
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Enters the new Safety Integrated password for the Terminal Module 54F (TM54F).
Dependency: A change made to the Safety Integrated password must be acknowledged in the following parameter:
Refer to: p10063
Description: Acknowledgement of the new Safety Integrated password for the Terminal Module 54F (TM54F).
Dependency: Refer to: p10062
Note: The new password entered into p10062 must be re-entered in order to acknowledge.
p10062 = p10063 = 0 is automatically set after the new Safety Integrated password has been successfully acknowl-
edged.
Description: Displays the Safety Integrated version for the Terminal Module 54F (TM54F).
Index: [0] = Safety Version (major release)
[1] = Safety Version (minor release)
[2] = Safety Version (baselevel or patch)
Dependency: Refer to: r9390, r9590, r9770, r9870, r9890
Note: Example:
r10090[0] = 2, r10090[1] = 3, r10090[2] = 1 --> SI version V02.03.01
Description: Displays PROFINET Name of Station.
Notice: An ASCII table (excerpt) can be found, for example, in the following List Manual:
p10062 SI password new TM54F / SI password new
TM54F_MA,
TM54F_SL
Can be changed: C2 Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: 2846
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0000 hex FFFF FFFF hex 0000 hex
p10063 SI password acknowledgement TM54F / SI ackn password
TM54F_MA,
TM54F_SL
Can be changed: C2 Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: 2846
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0000 hex FFFF FFFF hex 0000 hex
r10090[0...2] SI TM54F version / SI TM54F version
TM54F_MA,
TM54F_SL
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r61000[0...239] PROFINET Name of Station / PN Name of Station
CU_S (PROFINET) Can be changed: - Calculated: - Access level: 3
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -