List of parameters
Parameters
1-457
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the effective flux actual value of the current model. The value is referred to the rated motor flux.
Description: Displays the I component of the current model controller.
Description: Displays the output of the current model controller.
Description: Displays the magnetizing current of the current model in the d-axis.
Description: Displays the magnetizing current of the current model in the q-axis.
r1634 Current model, flux actual value / I_mod flux act val
VECTOR (n/M) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 6727
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r1635 Current model controller, I component / I_mod_ctrl I_comp
VECTOR (n/M) Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: 6727
P-Group: Closed-loop control Units group: 6_2 Unit selection: p0505
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r1636 Current model controller output / I_mod_ctrl outp
VECTOR (n/M) Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: 6727
P-Group: Closed-loop control Units group: 6_2 Unit selection: p0505
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r1637 Current model, magnetizing current, d axis / I_mod I_mag d-ax
VECTOR (n/M) Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: 6727
P-Group: Closed-loop control Units group: 6_2 Unit selection: p0505
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r1638 Current model, magnetizing current, q axis / I_mod I_mag q-ax
VECTOR (n/M) Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: 6727
P-Group: Closed-loop control Units group: 6_2 Unit selection: p0505
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]

Table of Contents

Related product manuals