Internal control/status words
Function Diagrams
2-1195
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-86 2534 – Status word monitoring functions 1
Function diagram
Reserved
Status word, monitoring functions 1
|n_act| <= speed threshold value 2 (p2155)
|n_act| > speed threshold value 2 (p2155)
1 = n_act >= 0
Reserved
Reserved
n_act > n_max
1 = Speed setpoint - actual value deviation within tolerance t_off
Reserved
Reserved
Reserved
9
10
8
7
6
5
4
3
2
1
0
Bit No. r2197
ZSW monitoring functions 1
r2197.7
r2197.6
r2197.2
r2197.1
r2197.3
<1> n
act
= smoothed speed actual value r2169 [8010.2].
<1>
<1>
From speed signals [8010.8]
From speed signals [8010.4]
1
p0115[3]
From speed signals [8010.8]
From speed signals [8010.4]
- 2534 -
87654321
fp_2534_51_eng.vsd
DO: SERVO, VECTOR, VECTORMV
SINAMICS
31.05.06 V02.05.00
Internal control/status words - Status word, monitoring functions 1