List of parameters
Parameters
1-549
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays how often the sign-of-life from the clock synchronous PROFIBUS/PROFINET master failed.
An appropriate fault is output when the tolerance, specified in p0925, is exceeded.
Dependency: Refer to: F01912
Description: Activates an automatic warm restart after changing the DP clock cycle has been changed.
p2066 = 0:
An attempt to change the DP clock cycle is rejected, and Alarm A01902 is output with alarm value = 9. In order that
the DP clock cycle becomes effective, a warm restart or POWER ON must be carried out.
p2066 = 1:
When the DP clock cycle is changed, an automatic warm restart is initiated (p0009 = 30, p0976 = 3). After booting
the modified DP clock cycle becomes effective. The automatic warm restart is only carried out if for all of the drives
the pulses have been canceled. Otherwise p0009 = 30 cannot be executed and an attempt to change the DP clock
cycle is rejected as for p2066 = 0.
Dependency: Refer to: A01902
Description: Displays the PROFIBUS address of the sender from which the process data (PZD) is received.
Index: [0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
Note: IF1: Interface 1
Value range:
0 - 125: Bus address of the sender
255: Not occupied
r2065 PROFIdrive master sign-of-life, diagnostics / PD mast-SoL diag
CU_CX32, CU_S,
SERVO, TM41, VEC-
TOR (n/M)
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: 2410
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
p2066 SYNC automatic warm restart / SYNC warm restart
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
0 1 0
r2074[0...4] IF1 PROFIdrive diagnostics bus address PZD receive / IF1diag addr recv
A_INF, B_INF,
CU_CX32, CU_S,
S_INF, TB30,
TM15DI_DO, TM31
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -