Siemens SINAMICS S Series - p0347[0...n] Motor de-excitation time; Mot t_de�excitat.; p0348[0...n] Speed at the start of field weakening Vdc = 600 V; Mot n_field weaken; p0348[0...n] Velocity at the start of field weakening Vdc = 600 V; Mot v_field weaken; p0349 System of units, motor equivalent circuit diagram data; Unit_sys mot ESB

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-155
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the de-magnetizing time (for induction motors) after the inverter pulses have been canceled.
The inverter pulses cannot be switched-in (enabled) within this delay time.
Note: The parameter is calculated using p0340 = 1, 3.
For induction motors, the result depends on the rotor time constant (r0384).
if this time is shortened too much, then this can result in an inadequate de-magnetization of the induction motor and
in an overcurrent condition when the pulses are subsequently enabled (only when the flying restart function is acti-
vated and the motor is rotating).
Description: Sets the speed at the start of field weakening for a DC link voltage of 600 V.
Dependency: Refer to: p0320, r0331
Caution: This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
Note: The parameter is automatically preset for motors from the motor list (p0301).
Description: Sets the velocity at the start of field weakening for a DC link voltage of 600 V.
Dependency: Refer to: p0320, r0331
Caution: This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
Note: The parameter is automatically preset for motors from the motor list (p0301).
Description: Sets the actual system of units for motor equivalent circuit diagram data.
p0347[0...n] Motor de-excitation time / Mot t_de-excitat.
VECTOR Can be changed: C2(3), U, T Calculated: CALC_MOD_REG Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.000 [s] 20.000 [s] 0.000 [s]
p0348[0...n] Speed at the start of field weakening Vdc = 600 V / Mot n_field weaken
SERVO Can be changed: C2(3), U, T Calculated: CALC_MOD_REG Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: 5722
P-Group: Motor Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.0 [RPM] 210000.0 [RPM] 0.0 [RPM]
p0348[0...n] Velocity at the start of field weakening Vdc = 600 V / Mot v_field weaken
SERVO (Lin) Can be changed: C2(3), U, T Calculated: CALC_MOD_REG Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: 5722
P-Group: Motor Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.0 [m/min] 1000.0 [m/min] 0.0 [m/min]
p0349 System of units, motor equivalent circuit diagram data / Unit_sys mot ESB
SERVO, VECTOR Can be changed: C2(3) Calculated: - Access level: 1
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
1 2 1