List of parameters
Parameters
1-309
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the effective supplementary setpoint. The value shown is the additional setpoint after scaling.
Description: Displays the effective supplementary setpoint. The value shown is the additional setpoint after scaling.
Description: Displays the total effective setpoint. The value indicates the sum of the effective main setpoint and supplementary
setpoint.
Description: Displays the total effective setpoint. The value indicates the sum of the effective main setpoint and supplementary
setpoint.
Description: Sets the lowest possible speed/velocity. This value is not fallen below in operation.
Note: The parameter value applies for both motor directions of rotation.
In exception cases, the motor can operate below this value (e.g. when reversing).
r1077 CO: Supplementary setpoint effective / Suppl setpoint eff
SERVO (Extended
setp), VECTOR
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 3030
P-Group: Setpoints Units group: 3_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [RPM] - [RPM] - [RPM]
r1077 CO: Supplementary setpoint effective / Suppl setpoint eff
SERVO (Extended
setp, Lin)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 3030
P-Group: Setpoints Units group: 4_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [m/min] - [m/min] - [m/min]
r1078 CO: Total setpoint effective / Total setpoint eff
SERVO (Extended
setp), VECTOR
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 3030
P-Group: Setpoints Units group: 3_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [RPM] - [RPM] - [RPM]
r1078 CO: Total setpoint effective / Total setpoint eff
SERVO (Extended
setp, Lin)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 3030
P-Group: Setpoints Units group: 4_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [m/min] - [m/min] - [m/min]
p1080[0...n] Minimum speed / Minimum speed
SERVO (Extended
setp), VECTOR
Can be changed: C2(1), T Calculated: - Access level: 1
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 3050
P-Group: Setpoints Units group: 3_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
0.000 [RPM] 19500.000 [RPM] 0.000 [RPM]