EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-162 5640 - Mode changeover, power;current limiting

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Diagrams
Servo control
2-1280
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-162 5640 – Mode changeover, power/current limiting
1
0
- 5640 -
Function diagram
87654321
fp_5640_01_eng.vsd
DO: SERVO
SINAMICS S
14.05.07 V02.05.00
Servo control - Mode changeover, power/current limiting
r1534
M_max_1
Mode changeover
r1535
M_min_1
From "upper/lower
torque limits"
[5630.8]
r1534
M_max_1
r1535
M_min_1
From "motoring/
regenerating
torque limits"
[5620.8]
r1534
r1535
Power limiting
r0063
n_act smooth
[4710.6]
P_max mot
0.00...10 000.00 [kW]
p1530 (100.00)
P_max gen
-10 000.00...0.00 [kW]
p1531 (100.00)
[5730.2]
Min
Min
-1
P_min
P_max
Iq_max_1
Iq_min_1
M2Iq torque factor
[5730.4]
Current limiting
M
P
n
M_max_3
M_min_3
1
0
Min
Min
<1>
[Nm]
[Nm]
M
P
n
P_stall
1000.00 µsp0115[1] (125.00 µs)
<1> M [Nm] =
<2>
r1533
Iq_max total
[5722.8]
-1
[5490.7]
1 = Torque limiting active
in motoring/regenerating mode
p1400.4
60 1000
2ʌ
P [kW]
n [RPM]
<0
0
<0
0
M_limit Vdc_max
M_limit Vdc_min
[5650.1]
[5650.1]
0
-1
1
>0
0
<0
0
-1
1
>0
0
<0

Table of Contents

Related product manuals