Siemens SINAMICS S Series - p4040 BI: TM31 signal source for terminal DI;DO 10; TM31 S_src DI;DO10; p4040 BI: TM41 signal source for terminal DI;DO 2; TM41 S_src DI;DO 2; p4040 BI: TM15 DI;DO signal source for terminal DI;DO 10; TM15 D S_srcDI;DO10; p4041 BI: TM31 signal source for terminal DI;DO 11; TM31 S_src DI;DO11

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-786
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the signal source for terminal DI/DO 10 (X541.4) of terminal module 31 (TM31).
Note: Prerequisite: The DI/DO must be set as an output (p4028.10 = 1).
DI/DO: Bidirectional Digital Input/Output
Description: Sets the signal source for terminal DI/DO 2 (X521.3) of terminal module 41 (TM41).
Note: Prerequisite: The DI/DO must be set as an output (p4028.10 = 1).
DI/DO: Bidirectional Digital Input/Output
Description: Sets the signal source for terminal DI/DO 10 (X521.4) of terminal module 15 (TM15).
Note: Prerequisite: The DI/DO must be set as an output (p4028.10 = 1).
DI/DO: Bidirectional Digital Input/Output
Description: Sets the signal source for terminal DI/DO 11 (X541.5) of terminal module 31 (TM31).
Note: Prerequisite: The DI/DO must be set as an output (p4028.11 = 1).
DI/DO: Bidirectional Digital Input/Output
p4040 BI: TM31 signal source for terminal DI/DO 10 / TM31 S_src DI/DO10
TM31 Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 9562
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p4040 BI: TM41 signal source for terminal DI/DO 2 / TM41 S_src DI/DO 2
TM41 Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 9662
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p4040 BI: TM15DI/DO signal source for terminal DI/DO 10 / TM15D S_srcDI/DO10
TM15DI_DO Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 9401
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p4041 BI: TM31 signal source for terminal DI/DO 11 / TM31 S_src DI/DO11
TM31 Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 1840, 9562
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0